Copyright @ 2009, www.arkautomation.com, All rights Reserved.
Extension Modules
Category 4 Application
Emergency Stop & Gate Monitoring
RS-NAGV
6 NO Safety Outputs
4 NC Auxiliary Outputs

Emergency Stop and Gate
Monitoring Applications |
RS-NAGX 5
Expansion Module

Used with a standard relay to
increase the number of outputs |
Connection Diagram |
RS-NAGV

|
 |
RS-NAGX 5

|
 |
Part Numbers |
Safe x4 |
Safe x4.1 |
Operation Voltage
|
24V AC/DC, 120V AC, 240 V AC |
|
Output Contacts |
6 NO Safety, 4 NC Auxiliary |
5 NO Safety, 1 NC Auxiliary |
Max. Contact Capacity |
4A (AC or DC) |
6A (AC or DC) |
Min. Contact Capacity |
10 mA |
1 mA |
Switching Capacity |
1500 VA (Resistive Load) |
2000 VA (Resistive Load) |
Power Consumption |
3 VA |
6 VA |
Start Up Delay / Fallback |
<150ms / <1000ms |
50ms |
Simultaneity |
75ms |
- |
Security |
6A quick acting or 4A time lag |
10A quick acting or 6A time lag |
Temperature Range |
-25°C to +55°C |
-25°C to +55°C |
Approvals |
CE, TUV |
CE, TUV, UL, cUL Pending |
|