Copyright @ 2009, www.arkautomation.com, All rights Reserved.
Mat and Edge Monitoring
Category 4 Application
Emergency Stop & Gate Monitoring
SAFE 2.2
Without Start Control Monitoring
(Automatic Reset)

Mat and Edge Control Monitoring Applications |
SAFE Z.2
Insures Simultaneous Closure of Two Buttons or Switches

Two Hand Anti Tie Down
Control Application |
Connection Diagram |
SAFE 2.2

|
 |
SAFE Z.2

|
 |
Part Numbers |
Safe 2.2 |
Safe Z.2 |
Operation Voltage
|
24V AC/DC |
24V AC/DC, 120V AC, 230 V AC
|
Output Contacts |
2 NO Safety |
2 NO Safety, 1 NC Auxiliary, 1 PNP |
Max. Contact Capacity |
6A (AC or DC) |
6A (AC or DC) |
Min. Contact Capacity |
1 mA |
1 mA |
Switching Capacity |
1500 VA (Resistive Load) |
2000 VA (Resistive Load) |
Power Consumption |
2.5 VA/ 2.5 W |
3 VA |
Start Up Delay / Fallback |
<50ms / <30ms |
<50ms / <25ms |
Simultaneity |
40ms |
.5s |
Security |
6.3A quick acting or 4A time lag |
6.3A quick acting or 4A time lag |
Temperature Range |
-25°C to +55°C |
-25°C to +55°C |
Approvals |
CE, BG, UL, cUL |
CE, BG, UL, cUL |
|